DT850L 디지털 멀티미터 - CHINYOO
CE (EMC/LVD) · RoHS · ISO 9001 중국 원저우 chingycai@chinyoo.com

DT850L 디지털 멀티미터

DT850L

  • DC 전압: 200m-2-20-200-600V ±1.5%
  • AC 전압: 200-600V ±3.0%
  • DC 전류: 200u-2m-20m-200m-10A ±3.0%
견적 요청

Key Features

  • LCD 크기: 46x18mm
  • 최대 표시: 1999
  • 배터리 부족 표시: 있음
  • 전원: 9V 6F22 배터리 1개
  • 제품 크기: 143x70x35mm
  • 제품 무게: 약 165g
  • 표준 액세서리: 본체(배터리 포함), 케이스, 테스트 리드, 설명서

Product Information

Series
디지털 멀티미터
Model
DT850L
SKU
194_DT850L digital multimeter
DC 전압
200m-2-20-200-600V ±1.5%
AC 전압
200-600V ±3.0%
DC 전류
200u-2m-20m-200m-10A ±3.0%

Specifications

Function DT850L
DC 전압 200m-2-20-200-600V ±1.5%
AC 전압 200-600V ±3.0%
DC 전류 200u-2m-20m-200m-10A ±3.0%
저항 200-2k-20k-200k-2MΩ ±2.0%

Application

This instrument is designed for electrical testing, installation and diagnostics across residential, commercial and industrial settings. Contact our team to discuss your specific application.

General Information

Packaging

포장: 컬러 박스 포장 수량: 60개/카톤 카톤 크기: 51.5x34.3x26CM 총중량 / 순중량: 15/14KG

Product Details

DT850L - White background
DT850L - Product details
DT850L - Application scenario

FAQ

기본형 디지털 멀티미터로 무엇을 측정하나요?

주요 측정 항목은 전압, 전류, 저항입니다. 교류와 직류의 지원 범위는 모델별 사양을 확인하세요.

가정에서 기본형으로 충분한가요?

가전 점검이나 전자 제작 등 많은 작업에 읽기 쉬운 기본형을 사용할 수 있습니다. 상용 전원 측정 시에는 측정 지점에 맞는 측정 카테고리도 확인하세요.

기본형의 정확도는 어느 정도인가요?

직류 전압 정확도는 모델에 따라 일반적으로 0.5~1 %입니다. 측정 범위별 상세 정확도는 모델 사양표에서 확인하세요.

유통업체에 도매로 공급하나요?

네. 원하는 모델과 수량을 알려 주시면 공장에서 도매 가격과 납기를 안내합니다.

How do I choose between the DT830, DT838 and DM101 for my first wholesale order?

For a first order, stock the DT830 or A830L as the entry price point and the DT838 or DM101 as the step-up tier. That gives you two price bands without tying up container space in slow SKUs, and you can add DT832, DT858L or XT802 later based on sell-through. If you are not sure which band sells in your market, order both in roughly equal quantities and reorder from the data. Compare the full functions on each model's specifications table before you fix the mix.

I sell to auto-repair shops and also to hardware stores. Should I split my basic DMM order across different models?

Most distributors run two tiers for this line: the DT830, DT830L and A830L for hardware and home channels, and the DT838, DT850L or DT858L for trade and auto customers who pay up for the step-up model. You can keep a single SKU to simplify stock, but splitting the order lets you match price bands to each channel. Tell us your expected split by customer type and we will quote per-model pricing for the full order.

Can you print my own brand on the meter and box for the basic DMM range?

Yes, we are the factory in Wenzhou, so we can print your brand on the meter face, the dial and the box for the basic DMM line, including DT830, DT832, DT838, DM101 and the rest of the range. For retail we offer printed color boxes with a fitted insert; for cost-sensitive programs we ship bulk packs with a plain carton and your label applied. Send us the models and packaging you want and we will confirm print minimums and artwork lead time for each model.

If units in a bulk order arrive dead or fail during the warranty period, how do we claim?

Return the defective meters with your order number and we will repair or replace them at our Wenzhou factory, and we check the same production lot so you can keep the remaining stock on the shelf with confidence. For wholesale orders we process claims by lot and can credit the replacement value against your next order to save on return freight. The process covers the whole basic DMM line, from the DT830L to the XT803.

Can a basic digital multimeter measure capacitance, or do I need a dedicated LCR meter?

Most of our multimeters have a capacitance range, so you do not need a separate LCR meter for the everyday job of finding a failed capacitor. The XT802 covers 4 nF to 40 mF at ±10.8%, and the DT6222 covers 4 nF to 4 mF at ±3.5%. A bench LCR meter is still the better instrument if you need leakage, ESR or dissipation factor, because a multimeter only reports capacitance.

Why does my multimeter read a different capacitance than the value printed on the capacitor?

The printed figure is a nominal value carrying its own tolerance, commonly ±5% for film and ±20% for electrolytics, so a small difference is normal and not a meter fault. A reading far outside that band usually means the capacitor has drifted or dried out rather than that the instrument is wrong. Check the meter against a capacitor of known value before you act on a surprising result.

Should I test a capacitor in circuit or desolder it first?

Discharge it, then lift at least one leg before measuring. In circuit, everything connected in parallel with the capacitor adds to the reading, and any discharge path makes the value drift while you watch it. With one leg lifted the reading settles within a second or two, and that is the number worth recording.

What capacitance range do I need for typical repair work?

Most repair work sits between 1 nF and 1000 µF: film and ceramic parts in the low nanofarad region, electrolytics in the microfarad region. The DT6222 covers 4 nF to 4 mF on a 4000-count display, so small values still have useful resolution. The XT802 spans 4 nF to 40 mF if your work reaches the large electrolytics as well.

도매 주문의 최소 수량은 얼마인가요?

소량 시험 주문부터 컨테이너 단위 주문까지 가능합니다. 원하는 모델과 수량을 알려 주시면 영업팀이 24시간 이내에 가격과 납기를 안내합니다.

자체 브랜드로 OEM 또는 ODM 생산이 가능한가요?

네. 2008년에 설립된 당사 공장은 라벨과 포장 맞춤 제작, 측정 범위 조정 등을 지원합니다. 필요한 사양을 보내 주세요.

대량 주문 전에 샘플을 평가할 수 있나요?

네. 샘플로 제작 품질과 교정 상태를 확인할 수 있습니다. 특송 배송은 보통 영업일 기준 3~7일이 걸립니다. 같은 모델을 처음 대량 주문할 때 샘플 비용을 정산해 드립니다. 문의 양식이나 이메일로 모델을 알려 주시면 견적을 보내 드리며 결제 후 발송합니다.

WA